Barboros Hayrettin Paşa Mah 1039 Sokak No : 4 GOP İstanbul
0212 537 49 57
0532 720 43 51

Teksan Diesel Generator Sets

Star InactiveStar InactiveStar InactiveStar InactiveStar Inactive
 
Doosan Generator TJ821DW5L

Doosan Generator TJ821DW5L

Doosan Generator
Standby Power ( ESP )
kVA: 821
kW: 656
Prime Power ( PRP )
kVA: 745
kW: 596
Canopied
W x L x H ( mm ): 1650x5360x2450
Weight ( kg ): 5196
Fuel Tank ( lt ): 970
Noise dB ( A ) @ 7m: 83
Open Skid
W x L x H ( mm ): 1650x3510x2250
Weight ( kg ): 4055
Fuel Tank ( lt ): 970
Noise dB ( A ) @ 7m: N/A
Engine
Manufacturer: DOOSAN
Model: DP222LC
Cylinder Configuration: V TYPE
No of Cylinders: 12
Displacement lt: 21,92
Stroke mm: 142
Bore mm: 128
Compression Ratio: 15:01
Aspiration: TURBOCHARGE-INTERCOOLER
Governor Type: ELECTRONIC
Cooling System: WATER
Coolant Capacity lt: 114
Lubrication Oil Capacity lt: 40
Electrical System VDC: 24
Speed / Frequency 50 Hz rpm: 1500 rpm / 50 Hz
Engine Gross Power ( Standby 50 Hz ) kW: 723
Fuel Consumption %110 ESP 50 Hz lt / h: 172,8
Fuel Consumption %100 PRP 50 Hz lt / h: 161
Fuel Consumption %75 PRP 50 Hz lt / h: 119,1
Fuel Consumption %50 PRP 50 Hz lt / h: 79,3
Exhaust Outlet Temperature 50 Hz °C: 635
Exhaust Gas Flow 50 Hz m3 / min: 108
Combustion Air Flow 50 Hz m3 / min: 45
Cooling Air Flow 50 Hz m3 / min: 860
Alternator
Manufacturer: LEROY-SOMER
Model: TAL049C
No of Phases: 3
Power Factor: 0,8
No of Bearings: SINGLE
No of Poles: 4
No of Leads: 6
Voltage Regulation ( Steady State ): ± %1
Insulation Class: H
Degree of Protection: IP 23
Excitation System: AVR (Automatic Voltage Regulator), Brushless
Connection Type: STAR
Total Harmonic Content ( No Load ): %3,5
Frequency Hz: 50
Voltage Output 50 Hz VAC: 230 / 400
Rated Power ( Standby ) 400 / 50 Hz kVA: 910
Rated Power ( Continuous ) 400 / 50 Hz kVA: 745
Efficiency ( 4 / 4 / 400 V / 50 Hz ) %: 93,7
Standard Equipments
Engine: In Teksan generator sets, leading engine brands that have state of the art technology and have compliance with ISO 8528, ISO 3046, BS 5514, DIN 6271 standarts, are being used. These engines with low fuel consumption, provide accurate speed setting and order, mount to the fuel pump, also have mechanic or electronic type governors.
Alternator: In products Teksan produced, leading alternator brands of the world that have state of the art technology, high quality, productivity and durability, are being used. All alternators, which pass necessary test process and found appropriate according to EC 60034-1; CEI EN 60034-1; BS 4999-5000; VDE 0530, NF 51- 100,111; OVE M-10, NEMA MG 1.22. standarts, have bearing system that does not need maintenance, with electronic type voltage regulator providing voltage setting.
Control Panel: Standard control panel, that is used in Teksan generator sets, ensures comfortable and safe usage. All measured and statistical parameters, operating modes, notice and alarms and condition of generator, are monitored easily from the control panel. On the front of the panel’s metal body has electronic control module and the emergency stop button and the panel’s metal body is made of steel sheet and is painted with electrostatic powder paint. Teksan offers panel design and solutions that comply with special requirements of customers as well as quality standard panels.
Chassis and Fuel Tank: Chassis is manufactured from steel that has features and durability for carrying burden of generator set. Thanks to its rigid structural design and anti-vibration mounts, it reduces vibration level to minimum. All chassis contain lifting lugs. Apart from chassises that are produce by Teksan, special solutions that design in accordance with customer desires, make transportation and positioning easier. In less than 1600 kVA power generator sets, fuel tank is produced integratedly to the chassis. In more than 1600 kVA power generator sets, rectangular type fuel tank is provided with generator set seperately. In all types of fuel tank have its level and indicator.
Cooling System: System, that consists of quality industrial - type radiator, expansion tank and cooler fan, keeps the temprature of generator set’s equipments constant at a proper level.
Canopy Features
Canopy Features:
  • Compatible with 2000/14/EC directives, certified noise emission level
  • 2 or 4 points transport possibility according to cabin size
  • Hidden exhaust inside the canopy
  • Emergency stop button located on the canopy
  • Improved air suction channel to ensure homogenous cooling in the canopy
  • Radiator air outlet and exhaust with designed towards above
  • Lid on cab that provides to be filled up water and antifreeze easily to the radiator
  • Amplified paint system against corrosion and rust
  • Improved performance in terms of sound insulation
  • Demounted parts that make transportation and maintenance easier
Optional Equipments:
  • Medium voltage alternator
  • Remote radiator applications
  • Automatic fuel filling system
  • Fuel tank, oil pan, dashboard, alternator, coil heaters
  • Alternator with double AVR and PMG
  • Synchronization systems
  • The generator output breaker
  • Grid-generator transfer switches
  • Accordance with the specific volume of demand-insulated cabins
  • Seismic solutions
  • Trailer
  • Remote monitoring
Control Panel Features-TJ 509-T:
  • The TJ-509T is a next generation genset control unit combining multi-functionality and wide communication possibilities together with a reliable and low cost design.
  • The unit complies and mostly exceeds world’s tightest safety, EMC, vibration and environmental standards for the industrial category.
  • Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS.
  • The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets from a single central location.
Functions:
  • AMF unit with uninterrupted transfer
  • ATS unit with uninterrupted transfer
  • Remote start controller
  • Manual start controller
  • Engine controller
  • Remote display & control unit
  • Waveform display of V & I
  • Harmonic analysis of V & I
  • CTs at genset or load side
Communications:
  • SM-GPRS
  • Web monitoring
  • Web programming
  • GSM-SMS
  • e-mail
  • USB Device
  • RS-232
  • J1939-CANBUS
Topologies:
  • 2 phase 3 wires, L1-L2
  • 2 phase 3 wires, L1-L3
  • 3 phase 3 wires, 3 CTs
  • 3 phase 3 wires, 2 CTs (L1-L2)
  • 3 phase 3 wires, 2 CTs (L1-L3)
  • 3 phase 4 wires, star
  • 3 phase 4 wires, delta
  • 1 phase 2 wires