Doosan Generator AD 220

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications.

All generator sets are factory build, and production tested.

Doosan Generator
General Characteristics
Model Name: AD 220
Frequency ( Hz ): 50
Fuel Type: Diesel
Engine Made and Model: DOOSAN - P086TI
Alternator Made and Model: Aksa - AK 4160
Control Panel Model: DSE 7320
Canopy: AK 50 TRP
3 Phase 50 Hz PF 0.8
STANDBY RATING ( ESP ):
  • Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source.
  • ESP is in accordance with ISO 8528-1.
  • Overload is not allowed.
PRIME RATING ( PRP ):
  • Applicable for supplying power to varying electrical load for unlimited hours.
  • PRP is in accordance with ISO 8528-1.
  • 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
VOLTAGE
Voltage: 400/231
STANDBY RATING ( ESP )
kVA: 220
kW: 176.0
PRIME RATING ( PRP )
kVA: 200
kW: 160.0
Standby Amper
Standby Amper: 317.55
ENGINE SPECIFICATIONS
Engine: DOOSAN
Engine Model: P086TI
NO. OF CYLINDERS AND BUILD: 6 cylinders - in line
BORE AND STROKE mm: 111 X 139
TOTAL DISPLACEMENT L: 8.071
Aspiration: Turbo Charged and Intercooled (Air to Air)
COMPRESSION RATIO: 16.4:1
RATED SPEED ( RPM ) d/dk: 1500
OIL CAPACITY L: 15.5
Standby Power ( kW/HP ): 199/270
Prime Power ( kW/HP ): 177/240
Block Heater QTY: 1
Block Heater Power ( Watt ): 15000
Fuel Type: Diesel
Injection Type and System: Direct
Type of Fuel Pump: Zexel P inline
Governor System: Electronic
Operating Voltage ( Vdc ): 24 Vdc
Battery and Capacity ( Qty / Ah ): 2x85
Charge Alternator ( A ): 45
Cooling Method: Water Cooled
Cooling Fan Air Flow ( m3 / min ): 250
Coolant Capacity ( engine only / with radiator ) ( lt ): 14/46
Air Filter: Dry Type
Fuel Cons Prime With %100 Load ( lt / hr ): 43.1
Fuel Cons Prime With %75 Load ( lt / hr ): 31.7
Fuel Cons Prime With %50 Load ( lt / hr ): 21.1
ALTERNATOR SPECIFICATIONS
Manufacturer: Aksa
Alternator Made and Model: AK 4160
Frequency ( Hz ): 50
Power (kVA): 200
DESIGN: Brushless
VOLTAGE: 400
Phase: 3
A.V.R.: SX440
Voltage Regulation ( + / - ): 1
Insulation System: H
Protection: IP22
Rated Power Factor: 0.8
WEIGHT COMP. GENERATOR ( Kg ): 626
COOLING AIR ( m³ / min ): 30.84
Open Type
DRY WEIGHT ( kg ) ( kg ): 1830
LENGTH ( mm ): 2690
WIDTH ( mm ): 1150
HEIGHT ( mm ): 1620
TANK CAPACITY ( lt ) ( Lt ): 380
CANOPY
CANOPY: AK 50 TRP
DRY WEIGHT kg ) ( kg ): 2205
LENGTH ( mm ): 3402
WIDTH ( mm ): 1217
HEIGHT ( mm ): 2008
TANK CAPACITY ( lt ) ( Lt ): 380
STANDARD SPECIFICATIONS
STANDARD SPECIFICATIONS:
  • Water cooled, Diesel engine
  • Radiator with mechanical fan
  • Protective grille for rotating and hot parts
  • Electric starter and charge alternator
  • Starting battery (with lead acid) including rack and cables
  • Engine coolant heater
  • Base frame design incorporates an integral fuel tank and anti-vibration isolators
  • Flexible fuel connection hoses
  • Single bearing, class H alternator
  • Industrial exhaust silencer and steel bellows supplied separately(for open sets)
  • Static battery charger
  • Manual for application and installation
OPTIONAL EQUIPMENTS
ENGINE:
  • Fuel-Water Seperator Filter
  • Oil heater
ALTERNATOR:
  • Anti-Condensation Heater
  • Over sized alternator
  • PMG excitation + AVR
  • Main line circuit breaker
CONTROL SYSTEM:
  • Automatic synchronising and power control system ( multi gen-set Parallel )
  • Transition synchronization with mains
  • Remote annunciator panel
  • Remote relay output
  • Alarm output relays
  • Remote communication with modem
  • Earth fault, single set
  • Charge Ammeter
TRANSFER SWITCH:
  • Three Pole Contactor
  • Four Pole Contactor
  • Three or four pole motor operated circuit breaker
OTHER ACCESSORIES:
  • Main Fuel Tank
  • Automatic or manual fuel filling system
  • Manual oil drain pump
  • Low and high fuel level alarm
  • Residential silencer
  • Enclosure: weater protective or sound attenuated
  • Duct adapter ( on radiator)
  • Inlet and outlet motorised louvers
  • Inlet and outlet acoustic baffles
  • Trailer
  • Tool kit for maintenance
  • 1500/3000 hours maintenance kit
  • Double wall chassis